PM9C1EK-AAAAAAA 1/8-DIN 2-Outputs
- One Universal Input
- Output #1 (E) - 5A Mechanical Relay (Form C)
- Output #2 (K) - 0.5A Solid State Relay (Form A)
- Operating 100 to 240VAC
- Auto-Tune PID Controller With Extensive Menu Options
- Standard Bus Communications
(edit with the Customer Reassurance module)
(edit with the Customer Reassurance module)
(edit with the Customer Reassurance module)
WATLOW EZ-ZONE® PM9C1EK-AAAAAAA
- This unit can control a compressor, motor, pressure, valve, humidity, as well as thermal processes.
- The serial communications when used with the free WATLOW software, saves time of controller setup.
- P3T armor sealing system Complies to NEMA 4X, IP66
Updated EZ-ZONE® Features
- Also available in 12 ~ 40VDC or 20 ~ 28VAC Model PM9C3EK-AAAAAAA
- Also available in Vertical Panel Mount Model PM8C1EK-AAAAAAA
Universal Input
- This can be a thermocouple grounded or ungrounded
- It can be an RTD 2-wire or 3-wire
- It can be 0-20mA or 0-50mV
Electro-Mechanical Relay Form C Specifications:
- Maximum Resistive Load 5A at 240VAC Or 30VDC
- 20mA at 24V Minimum Load
- Rated For Pilot Duty 125VA at 120/240VAC and 25VA at 24VAC
- Single Pole Double Throw Normally Open Contact
- 100,000 Cycles at Rated Load
- Output Does Not Supply Power
- For use on AC or DC Loads
Solid State Relay Form A Specifications:
- Maximum Resistive Load 0.5A at 20 ~ 264VAC
- Rated For Pilot Duty 20VA 120/240VAC
- Single Pole Single Throw Normally Open Contact
- Opto Isolated Without Contact Suppression
- Off State Leakage Maximum 105mA
- Output Does Not Supply Power
- Not for use on DC Loads
NOTE: Switching Pilot Duty Devices Such As Control Coils For Relays Or Contactors Produces An Electro-Magnetic Force When De-Energizing Those Type Of Loads. To Protect The Controller's Electronic Circuitry From The Inductive User Load, The Use Of An RC Suppressor Also Known As A Snubber Device Should Be Wired Between The Load And The Load Output Terminal Of The Controller. An Exception Is The Use Of Watlow Solid State Relays Having Internal RC Suppression.
Two Wire Bus Communication Interface Type EIA-485 Also Known As RS-485 Comes Standard With All PM Series Controllers Which Can Provide An Easy Alternative to Setting Up Program Menu Options. Various Profiles Can Be Configured And Saved As Files And Can Be Up Loaded To Other PM Controllers. USB To Serial Converter Is Required To Connect The PM Controller To Any Computer With A USB Port.
Review the above tabs for Data Sheets, FAQ's & Attachments for more specifics and operator's manual.
Data sheet
- PROGRAM FEATURES
- Advanced Auto-Tune PID Control Algorithm
- AGENCY APPROVALS
- UL Listed, CSA, CE, RoHS, W.E.E.E. FM
- WARRANTY
- Three Years
- OTHER FEATURES
- IP2X Increases Safety For Installers And Operators