Din-A-Mite D Current De-Ratings Shown Are Based On Natural Convection
176°F....50-Amp |
158°F....60-Amp |
140°F....70-Amp |
122°F....80-Amp |
104°F....90-Amp |
86°F......100-Amp |
Din-A-Mite D - Operator Interface
- Control input and indication light
- Alarm output and indication light
Din-A-Mite D - Operating Environment
- 0 to 90% non-condensing relative humidity
- Storage temperature: -40°F to 185°F (-40°c to 85°c)
- Operating temperature: 32°F to 185°F (0°c to 85°c)
- Insulation tested to 3,000 meters
Din-A-Mite D - Terminals
- Control input terminals: compression 26 to 12 AWG max torque 4.4 in/lb
- Line & Load terminals: compression 6 to 2 AWG max torque 80 ~ 90 in/lb
Din-A-Mite D - Mounting
- Back-Panel mounting holes for #10 fastener size
- Fits same mounting pattern as 100A Mercury Relay
Din-A-Mite D - Agency Approvals
- CE with proper filter: 204/108/EC electromagnetic compatibility directive EN 61326-1: industrial immunity Class A emissions not suitable for Class B environments, 2006/95/EC low voltage directive EN50178 safety requirements.
- UL-508 listed and C-UL file E73741
- Shock and vibration tested to 2g, 10-Hz ~ 150-Hz