Din-A-Mite B Current De-Ratings Shown Are Based On Natural Convection
176°F....20-Amp
158°F....25-Amp
140°F....30-Amp
122°F....35-Amp
Din-A-Mite B Operator Interface
Control input and indication light
Alarm output and indication light
Din-A-Mite B Operating Environment
0 to 90% non-condensing relative humidity
Storage temperature: -40°F to 185°F(-40°c to 85°c)
Operating temperature: -29°F to 176°F(-34°c to 80°c)
Insulation tested to 3,000 meters
Din-A-Mite B Terminals
Control input terminals: compression 24 to 16 AWG max torque 4.4 in/lb
Line & Load terminals: compression 14 to 4 AWG max torque 24 in/lb
Din-A-Mite B Mounting & Dimensions
DIN-Rail 35mm X 7.5mm DIN EN 50022
Back-Panel four mounting holes #6 to #8 fastener size
3.7"H x 3.3"W x 4.9"D 1.5/Lb.s
Din-A-Mite B Agency Approvals
CE with proper filter: 204/108/EC electromagnetic compatibility directive EN 61326-1: industrial immunity Class A emissions not suitable for Class B environments, 2006/95/EC low voltage directive EN50178 safety requirements installation category III, pollution degree 2.