• Payment & Delivery

    Payment & Delivery
Immersion Heater Screw Plug | BLR717L3S
  • Immersion Heater Screw Plug | BLR717L3S
  • BLR717L3S Dimensions
  • BLR717L3S Drawing
  • Watlow BLR717L3S

BLR717L5C screw plug immersion heater

BLR717L5C
  • Comes wired 480v 3-phase delta in an explosion proof wiring enclosure
  • It has (3) 316-ss passivated 17.625-inch immersed length heating elements
  • with expoxy resin end seals rated at 194ºF and provide up to 7.5kw
  • Also included is an integral thermowell for a sensor (sensor not included)
  • The heater has no heat the first 4.125-inches from the 2-1/2-inch NPT screw plug
  • and has an approximate shipping weight of 10/Lbs.
$2,389.00
Tax included Ship 5-days after order entry
Quantity
In Stock

  Security policy

(edit with the Customer Reassurance module)

  Delivery policy

(edit with the Customer Reassurance module)

  Return policy

(edit with the Customer Reassurance module)

Description

2-1/2"NPT screw plug immersion heater | BLR717L5C

Applications that require heating Deionized/Demineralized water include:

  • Steam boilers and cooling systems
  • Cleaning processes
  • Manufacturing lead-acid batteries
  • Electronics manufacturing
  • Manufacturing cosmetics and personal care products
  • Medical and pharmaceutical manufacturing
  • Car washes

Features & Benefits of the Watlow® immersion heater

The integral thermowell provides a convenient method for temperature sensor insertion and allowing a replacement without draining the fluid being heated. The CSA approved general purpose enclosure can be rotated to simplify connecting to existing conduits. The WATROD™ hairpin bend is re-compacted to maintain the mineral insulation density and maintain the dielectric strength and heat transfer efficiency. The heating elements have a bright annealing passivation for corrosion resistance and the screw plug is 316SS.

NOTE: A NEMA-7 enclosure designated for locations classified as Class-1, Division-1, Groups A,B,C, or D as defined in NFPA 70 is installed on this heater; however, is NOT CERTIFIED as installed on the heater. To obtain CSA certification as explosion proof Class-1, Groups B,C,D as installed on the heater, the end user must provide Watlow® the following intended process conditions: operating temperature, operating pressure, media type being heated, including the installation orientation of the heater (horizontal or vertical).

One conduit hub is supplied as per drawing.

Product Details
BLR717L5C
1 Item
New

Data sheet

Enclosure
CSA general purpose
Thermostat
not included
Line power
240v AC 3-phase delta
Wattage
7500 watt
Mounting
2-1/2" NPT screw plug
Immersion Length
17.625"
Weight
10-lbs