List of products by brand Watlow Electric Mfg.
Watlow Designs And Manufactures Industrial Heaters, Temperature Sensors, Controllers And Supporting Software As Well As Assemblies – All Of The Components Of A Thermal System. Watlow Holds More Than 200 Patents And Has More Than 2,000 Employees Working In 12 Facilities In The United States, Mexico, Europe and Asia.
Watlow Holds More Than 200 Patents And Employs 2,000 Employees Working In 12 Manufacturing Facilities In The United States, Mexico, Europe and Asia. Watlow Designs And Manufactures Industrial Heaters, Sensors And Controllers.
Showing 373-384 of 431 item(s)
Reference:
DC30-24K2-S000
Brand:
Watlow Electric Mfg.
Line Voltage 100~240Vac 3-Phase, 3-Leg control
Control Voltage 100~120Vac
Back to Back SCR Design
Zero Cross Switching Up-To 35A@104°F (see table below)
200Ka Short Circuit Current Rating with proper fusing
With Shorted SCR Alarm Protection
Reference:
DC30-60C0-0000
Brand:
Watlow Electric Mfg.
Line Voltage 277~600Vac 3-Phase, 3-Leg control
Control Voltage 4.5~32Vdc
8mA Maximum Control Current @4.5Vdc
Back to Back SCR Design
Zero Cross Switching Up-To 35A@104°F (see table below)
200Ka Short Circuit Current Rating with proper fusing
Available with Shorted SCR Alarm, Watlow DC30-60C0-S000
Reference:
DC30-60C0-S000
Brand:
Watlow Electric Mfg.
Line Voltage 277~600Vac 3-Phase, 3-Leg control
Control Voltage 4.5~32Vdc
8mA Maximum Control Current @4.5Vdc
Back to Back SCR Design
Zero Cross Switching Up-To 35A@104°F (see table below)
200Ka Short Circuit Current Rating with proper fusing
With Shorted SCR Alarm Protection
Reference:
DC30-60F0-0000
Brand:
Watlow Electric Mfg.
Line Voltage 277~600Vac 3-Phase 3-Controlled Legs
4~20mA Proportional Control
Din Rail Mount or Flat Panel Mounting
Back to Back SCR Design
Zero Cross Switching Up-To 35A@104°F (see table below)
Available with Shorted SCR Alarm, Watlow DC30-60F0-S000
Reference:
SHV1J5AL-24W
Brand:
Watlow Electric Mfg.
1-PC Mica Insulated Band Heater
700w 120v
36" Fiberglass Insulated Leads
Strapless Wedge Lock Mounting
Aluminized Steel Sheath
Reference:
DC30-60F0-S000
Brand:
Watlow Electric Mfg.
Line Voltage 277~600Vac 3-Phase 3-Controlled Legs
4~20mA Proportional Control
Din Rail Mount or Flat Panel Mounting
Back to Back SCR Design
Zero Cross Switching Up-To 35A@104°F (see table below)
With Shorted SCR Alarm Protection
Reference:
DC30-60K1-0000
Brand:
Watlow Electric Mfg.
Line Voltage 277~600Vac 3-Phase, 3-Leg control
Control Voltage 24~48Vac
Back to Back SCR Design
Zero Cross Switching Up-To 35A@104°F (see table below)
200Ka Short Circuit Current Rating with proper fusing
Reference:
DC30-60K2-0000
Brand:
Watlow Electric Mfg.
Line Voltage 277~600Vac 3-Phase, 3-Leg control
Control Voltage 100~120Vac
Back to Back SCR Design
Zero Cross Switching Up-To 35A@104°F (see table below)
200Ka Short Circuit Current Rating with proper fusing
Available with Shorted SCR Alarm, Watlow DC30-60K2-S000
Reference:
DC30-60K2-S000
Brand:
Watlow Electric Mfg.
Line Voltage 277~600Vac 3-Phase, 3-Leg control
Control Voltage 100~120Vac
Back to Back SCR Design
Zero Cross Switching Up-To 35A@104°F (see table below)
200Ka Short Circuit Current Rating with proper fusing
With Shorted SCR Alarm Protection
Reference:
DC30-60K3-0000
Brand:
Watlow Electric Mfg.
Line Voltage 277~600Vac 3-Phase, 3-Leg control
Control Voltage 200~240Vac
Back to Back SCR Design
Zero Cross Switching Up-To 35A@104°F (see table below)
200Ka Short Circuit Current Rating with proper fusing
Available with Shorted SCR Alarm, Watlow DC30-60K3-S000
View attachments tab below for literature and instructions.
Reference:
DD10-02F0-0000
Brand:
Watlow Electric Mfg.
Line Voltage 24~48Vac 1-Phase
Control Input 4 ~ 20mA-dc Proportional
Back to Back SCR Design
Zero Cross Switching Up-To 100A@86°F (see table below)
200Ka Short Circuit Current Rating with proper fusing
Available with Shorted SCR Alarm Watlow DD10-02F0-S000
View attachments tab below for literature and instructions.
Reference:
DD10-24C0-0000
Brand:
Watlow Electric Mfg.
Line Voltage 100~240Vac 1-Phase
Control Voltage 4.5~32Vdc
6mA Maximum Control Current @4.5Vdc
Back to Back SCR Design
Zero Cross Switching Up-To 100A@86°F (see table below)
200Ka Short Circuit Current Rating with proper fusing
Available with Shorted SCR Alarm Watlow DD10-24C0-S000
View attachments tab below for literature and instructions.