• Payment & Delivery

    Payment & Delivery
DD10-60K2-S000 Watlow Din-A-Mite D
  • DD10-60K2-S000 Watlow Din-A-Mite D

DD10-60K2-S000 Watlow Din-A-Mite D

DD10-60K2-S000
  • Line Voltage 277~600Vac 1-Phase
  • Control Voltage 100~120Vac
  • Back to Back SCR Design
  • With Shorted SCR Alarm
  • Zero Cross Switching Up-To 100A@86°F (see table below)
  • 200Ka Short Circuit Current Rating with proper fuse

View attachments tab below for literature and instructions.

$903.00
Tax included
Quantity
In Stock

  Security policy

(edit with the Customer Reassurance module)

  Delivery policy

(edit with the Customer Reassurance module)

  Return policy

(edit with the Customer Reassurance module)

Description

Din-A-Mite D Current De-Ratings Shown Are Based On Natural Convection

   176°F....50-Amp    158°F....60-Amp    140°F....70-Amp    122°F....80-Amp    104°F....90-Amp    86°F......100-Amp

Din-A-Mite D - Operator Interface

  • Control input and indication light
  • Alarm output and indication light

Din-A-Mite D - Operating Environment

  • 0 to 90% non-condensing relative humidity
  • Storage temperature: -40°F to 185°F (-40°c to 85°c)
  • Operating temperature: 32°F to 185°F (0°c to 85°c)
  • Insulation tested to 3,000 meters

Din-A-Mite D - Terminals

  • Control input terminals: compression 26 to 12 AWG max torque 4.4 in/lb
  • Line & Load terminals: compression 6 to 2 AWG max torque 80 ~ 90 in/lb

Din-A-Mite D - Mounting

  • Back-Panel mounting holes for #10 fastener size
  • Fits same mounting pattern as 100A Mercury Relay

Din-A-Mite D - Agency Approvals

  • CE with proper filter: 204/108/EC electromagnetic compatibility directive EN 61326-1: industrial immunity Class A emissions not suitable for Class B environments, 2006/95/EC low voltage directive EN50178 safety requirements.
  • UL-508 listed and C-UL file E73741
  • Shock and vibration tested to 2g, 10-Hz ~ 150-Hz
Product Details
DD10-60K2-S000
0
2 Items