List of products by brand Watlow Electric Mfg.
Watlow Designs And Manufactures Industrial Heaters, Temperature Sensors, Controllers And Supporting Software As Well As Assemblies – All Of The Components Of A Thermal System. Watlow Holds More Than 200 Patents And Has More Than 2,000 Employees Working In 12 Facilities In The United States, Mexico, Europe and Asia.
Watlow Holds More Than 200 Patents And Employs 2,000 Employees Working In 12 Manufacturing Facilities In The United States, Mexico, Europe and Asia. Watlow Designs And Manufactures Industrial Heaters, Sensors And Controllers.
Showing 385-396 of 431 item(s)
Reference:
DD10-24C0-S000
Brand:
Watlow Electric Mfg.
Line Voltage 100~240Vac 1-Phase
Control Voltage 4.5~32Vdc
6mA Maximum Control Current @4.5Vdc
Back to Back SCR Design
With Shorted SCR Alarm
Zero Cross Switching Up-To 100A@86°F (see table below)
200Ka Short Circuit Current Rating with proper fusing
View attachments tab below for literature and instructions.
Reference:
B1N1JN6
Brand:
Watlow Electric Mfg.
1-PC Mica Insulated Band Heater
250w 240v
12" Fiberglass Insulated Leads
Stainless Steel Braid Over Leads
Strap Mounted
Aluminized Steel Sheath
Reference:
DD10-24F0-0000
Brand:
Watlow Electric Mfg.
Line Voltage 100~240Vac 1-Phase
Proportional Control Input 4 ~ 20mA-dc
Back to Back SCR Design
Zero Cross Switching Up-To 100A@86°F (see table below)
200Ka Short Circuit Current Rating with proper fusing
Available with Shorted SCR Alarm Watlow DD10-24F0-S000
View attachments tab below for literature and instructions.
Reference:
DD10-24F0-S000
Brand:
Watlow Electric Mfg.
Line Voltage 100~240Vac 1-Phase
Proportional Control Input 4 ~ 20mA-dc
Back to Back SCR Design
Includes an Alarm for Shorted SCR
Zero Cross Switching Up-To 100A@86°F (see table below)
200Ka Short Circuit Current Rating with proper fusing
View attachments tab below for literature and instructions.
Reference:
DD10-24K2-0000
Brand:
Watlow Electric Mfg.
Line Voltage 100~240Vac 1-Phase
Control Voltage 100~120Vac
Back to Back SCR Design
Zero Cross Switching Up-To 100A@86°F (see table below)
200Ka Short Circuit Current Rating with proper fuse
Available with Shorted SCR Alarm DD10-24K2-S000
View attachments tab below for literature and instructions.
Reference:
DD10-24K2-S000
Brand:
Watlow Electric Mfg.
Line Voltage 100~240Vac 1-Phase
Control Voltage 100~120Vac
Back to Back SCR Design
With Alarm for Shorted SCR
Zero Cross Switching Up-To 100A@86°F (see table below)
200Ka Short Circuit Current Rating with proper fuse
View attachments tab below for literature and instructions.
Reference:
DD10-24K3-S000
Brand:
Watlow Electric Mfg.
Line Voltage 100~240Vac 1-Phase
Control Voltage 200~240Vac
Back to Back SCR Design
With Alarm for Shorted SCR
Zero Cross Switching Up-To 100A@86°F (see table below)
200Ka Short Circuit Current Rating with proper fuse
View attachments tab below for literature and instructions.
Reference:
DD10-48C0-0000
Brand:
Watlow Electric Mfg.
Line Voltage 277~480Vac 1-Phase
Control Voltage 4.5~32Vdc
6mA Maximum Control Current @4.5Vdc
Back to Back SCR Design
Zero Cross Switching Up-To 100A@86°F (see table below)
200Ka Short Circuit Current Rating with proper fusing
Available with Shorted SCR Alarm Watlow DD10-48C0-S000
View attachments tab below for literature and instructions.
Reference:
B1N2AG2F
Brand:
Watlow Electric Mfg.
1-PC Mica Insulated Band Heater
300w 240v
144" Fiberglass Insulated Leads
Stainless Steel Braid Over Leads
Strap Mounted
Aluminized Steel Sheath
Reference:
DD10-48C0-S000
Brand:
Watlow Electric Mfg.
Line Voltage 277~480Vac 1-Phase
Control Voltage 4.5~32Vdc
6mA Maximum Control Current @4.5Vdc
Back to Back SCR Design
With Alarm for Shorted SCR
Zero Cross Switching Up-To 100A@86°F (see table below)
200Ka Short Circuit Current Rating with proper fusing
View attachments tab below for literature and instructions.
Reference:
DD10-48F0-0000
Brand:
Watlow Electric Mfg.
Line Voltage 277~480Vac 1-Phase
Proportional Control Input 4 ~ 20mA-dc
Back to Back SCR Design
Zero Cross Switching Up-To 100A@86°F (see table below)
200Ka Short Circuit Current Rating with proper fusing
Available with Shorted SCR Alarm Watlow DD10-48F0-S000
View attachments tab below for literature and instructions.
Reference:
DD10-48F0-S000
Brand:
Watlow Electric Mfg.
Line Voltage 277~480Vac 1-Phase
Proportional Control Input 4 ~ 20mA-dc
Back to Back SCR Design
With Alarm for Shorted SCR
Zero Cross Switching Up-To 100A@86°F (see table below)
200Ka Short Circuit Current Rating with proper fusing
View attachments tab below for literature and instructions.