On ~ Off Analog Controller Input "T" Thermocouple Output SPST 3-Amp Mechanical Relay 120Vac Line Voltage Integral Set Point Front Dial Dual Scale 14°F ~ 212°F, -10°c ~ 100°c Panel Mount with .39"OD Hole in Center
Two Switched DC/Open Collector Outputs PID Auto Tune Panel Mount Controller Single User Selectable Input: T/C, RTD, 4~20ma, 0~5Vdc 100 ~ 240Vac Line Voltage Dual Four Digit Red/Green Display Nema 4x & CE Rated For "How To" Videos and More Information Visit Google+ Plus
Dual Output Mech-Relays 5-Amp SPDT PID Auto Tune Panel Mount Controller Single Selectable Input: T/C, RTD, 4~20ma, 0~5Vd 100 ~ 240Vac Line Voltage Dual Four Digit Display Red/Green IP65 Rated For "How To" Videos and More Information Visit Google+ Plus
"J" Thermocouple Input One 5-Amp N/O or N/C Output Contacts Analog Non-Indicating Temperature Controller 5F to 50F Proportional Band Front Panel Dial Adjustable Manual Reset 100% of Proportional Band Front Panel Adjustable 2 to 20 Seconds internal Adjust Cycle Time Dual Farenheit and Celcius Scales
This is an obsolete 1/16 DIN temperature controller with a user selectable input via dip switch settings that accepts type J, K, T, N or S thermocouple, RTD or process input 4~20mA. 0~5vDC. It has one switched DC non-isolated contact output that can be set for heating or cooling programable for PID or on/off control with ramp to set point capability. Use Ez-Zone® PM Express
This is an obsolete 1/16 DIN temperature controller with a user selectable input via dip switch settings that accepts type J, K, T, N or S thermocouple, RTD or process input 4~20mA. 0~5vDC. It has two switched DC non-isolated contact output that can be set for heating or cooling programable for PID or on/off control with ramp to set point capability. Use Ez-Zone® PM Express
This is an obsolete 1/16 DIN temperature controller with a user selectable input via dip switch settings that accepts type J, K, T, N or S thermocouple, RTD or process input 4~20mA. 0~5vDC. It has one switched DC non-isolated contact output that can be set for heating or cooling programable for PID or on/off control with ramp to set point capability. Use Ez-Zone® PM Express
This is an obsolete 1/16 DIN temperature controller with a user selectable input via dip switch settings that accepts type J, K, T, N or S thermocouple, RTD or process input 4~20mA. 0~5vDC. It has two switched DC non-isolated contact output that can be set for heating or cooling programable for PID or on/off control with ramp to set point capability. Use Ez-Zone® PM Express
This obsolete temperature controller had a selectable input via dip switch settings for thermocouples type J, K, T, N or S , RTD or process input 4~20mA. 0~5vDC. It had one switched DC non-isolated output and one 5A mech-relay output. User programable operation for heating or cooling with selectable control of PID or on/off with ramp to set point capability. Use Ez-Zone® PM Express
This obsolete temperature controller had a selectable input via dip switch settings for thermocouples type J, K, T, N or S , RTD or process input 4~20mA. 0~5vDC. It had one switched DC non-isolated output and one 5A mech-relay output. User programable operation for heating or cooling with selectable control of PID or on/off with ramp to set point capability. Use Ez-Zone® PM Express
This obsolete temperature controller had a selectable input via dip switch settings for thermocouples type J, K, T, N or S , RTD or process input 4~20mA. 0~5vDC. It had one switched DC non-isolated output and one 0.5A ssr output. User programable operation for heating or cooling with selectable control of PID or on/off with ramp to set point capability. Use Ez-Zone® PM Express
This obsolete temperature controller had a selectable input via dip switch settings for thermocouples type J, K, T, N or S , RTD or process input 4~20mA. 0~5vDC. It had one switched DC non-isolated output and one 0.5A ssr output. User programable operation for heating or cooling with selectable control of PID or on/off with ramp to set point capability. Use Ez-Zone® PM Express
This is an obsolete 1/16 DIN temperature controller with a user selectable input via dip switch settings that accepts type J, K, T, N or S thermocouple, RTD or process input 4~20mA. 0~5vDC. It has one mech-relay 5A SPDT output that can be set for heating or cooling programable for PID or on/off control with ramp to set point capability. Recommended replacement is PM6C1EA-BAAABAA
This is an obsolete 1/16 DIN temperature controller with a user selectable input via dip switch settings that accepts type J, K, T, N or S thermocouple, RTD or process input 4~20mA. 0~5vDC. It has one mech-relay 5A SPDT output that can be set for heating or cooling programable for PID or on/off control with ramp to set point capability. Use Ez-Zone® PM Express
This obsolete temperature controller had a selectable input via dip switch settings for thermocouples type J, K, T, N or S , RTD or process input 4~20mA. 0~5vDC. It had one mech-relay output and one switched DC non-isolated output. User programable operation for heating or cooling with selectable control of PID or on/off with ramp to set point capability. Use Ez-Zone® PM Express
This obsolete temperature controller had a selectable input via dip switch settings for thermocouples type J, K, T, N or S , RTD or process input 4~20mA. 0~5vDC. It had one mech-relay output and one switched DC non-isolated output. User programable operation for heating or cooling with selectable control of PID or on/off with ramp to set point capability. Use Ez-Zone® PM Express
This obsolete temperature controller had a selectable input via dip switch settings for thermocouples type J, K, T, N or S , RTD or process input 4~20mA. 0~5vDC. It had two 5A single pole double throw mech-relay outputs. User programable operation for heating or cooling with selectable control of PID or on/off with ramp to set point capability. Use Ez-Zone® PM Express
This obsolete temperature controller had a selectable input via dip switch settings for thermocouples type J, K, T, N or S , RTD or process input 4~20mA. 0~5vDC. It had two 5A single pole double throw mech-relay outputs. User programable operation for heating or cooling with selectable control of PID or on/off with ramp to set point capability. Use Ez-Zone® PM Express
Two solid state 0.5A SP/ST relay outputs PID Auto Tune Panel Mount Controller Single User Selectable Input: T/C, RTD, 4~20ma, 0~5Vdc 100 ~ 240Vac Line Voltage Dual Four Digit Red/Green Display No nema 4x & CE Rating For "How To" Videos and More Information Visit Google+ Plus