Usado principalmente para la protección de los semiconductores 13/32"OD x 1-1/2"L (10mm x 38mm) Rated 700Vac 500Vdc Inturrupting Clasificación 160Ka@690Vac I²T Eliminación Clasificación 30A²Seconds @690Vac I²T Eliminación Clasificación 20A²Seconds @480Vac I²T Eliminación Clasificación 12A²Seconds @240Vac I²T Eliminación Clasificación 10A²Seconds @120Vac
Primarily Used For Semiconductor Protection 13/32"OD x 1-1/2"L (10mm x 38mm) Rated 700Vac 500Vdc Inturrupting Rating 160Ka@690Vac I²T Clearing Rating 40A²Seconds @690Vac I²T Clearing Rating 27A²Seconds @480Vac I²T Clearing Rating 16A²Seconds @240Vac I²T Clearing Rating 13A²Seconds @120Vac
Primarily Used For Semiconductor Protection 13/32"OD x 1-1/2"L (10mm x 38mm) Rated 700Vac 500Vdc Inturrupting Rating 160Ka@690Vac I²T Clearing Rating 35A²Seconds @690Vac I²T Clearing Rating 23A²Seconds @480Vac I²T Clearing Rating 14A²Seconds @240Vac I²T Clearing Rating 11A²Seconds @120Vac
Primarily Used For Semiconductor Protection 13/32"OD x 1-1/2"L (10mm x 38mm) Rated 700Vac 500Vdc Inturrupting Rating 160Ka@690Vac I²T Clearing Rating 55A²Seconds @690Vac I²T Clearing Rating 37A²Seconds @480Vac I²T Clearing Rating 22A²Seconds @240Vac I²T Clearing Rating 18A²Seconds @120Vac
Primarily Used For Semiconductor Protection 13/32"OD x 1-1/2"L (10mm x 38mm) Rated 700Vac 500Vdc Inturrupting Rating 160Ka@690Vac I²T Clearing Rating 90A²Seconds @690Vac I²T Clearing Rating 60A²Seconds @480Vac I²T Clearing Rating 36A²Seconds @240Vac I²T Clearing Rating 29A²Seconds @120Vac
Primarily Used For Semiconductor Protection 13/32"OD x 1-1/2"L (10mm x 38mm) Rated 700Vac 500Vdc Inturrupting Rating 160Ka@690Vac I²T Clearing Rating 140A²Seconds @690Vac I²T Clearing Rating 94A²Seconds @480Vac I²T Clearing Rating 56A²Seconds @240Vac I²T Clearing Rating 45A²Seconds @120Vac
Primarily Used For Semiconductor Protection13/32"OD x 1-1/2"L (10mm x 38mm) Rated 700Vac 500Vdc Inturrupting Rating 160Ka@690Vac I²T Clearing Rating 245A²Seconds @690Vac I²T Clearing Rating 164A²Seconds @480Vac I²T Clearing Rating 98A²Seconds @240Vac I²T Clearing Rating 79A²Seconds @120Vac
Primarily Used For Semiconductor Protection13/32"OD x 1-1/2"L (10mm x 38mm) Rated 700Vac 500Vdc Inturrupting Rating 160Ka@690Vac I²T Clearing Rating 425A²Seconds @690Vac I²T Clearing Rating 285A²Seconds @480Vac I²T Clearing Rating 170A²Seconds @240Vac I²T Clearing Rating 136A²Seconds @120Vac
Primarily Used For Semiconductor Protection13/32"OD x 1-1/2"L (10mm x 38mm) Rated 700Vac 500Vdc Inturrupting Rating 160Ka@690Vac I²T Clearing Rating 675A²Seconds @690Vac I²T Clearing Rating 452A²Seconds @480Vac I²T Clearing Rating 270A²Seconds @240Vac I²T Clearing Rating 216A²Seconds @120Vac
Primarily Used For Semiconductor Protection13/32"OD x 1-1/2"L (10mm x 38mm) Rated 700Vac 500Vdc Inturrupting Rating 160Ka@690Vac I²T Clearing Rating 945A²Seconds @690Vac I²T Clearing Rating 634A²Seconds @480Vac I²T Clearing Rating 378A²Seconds @240Vac I²T Clearing Rating 302A²Seconds @120Vac
Primarily Used For Semiconductor Protection 13/32"OD x 1-1/2"L (10mm x 38mm) 600V ac/dc Rated Inturrupting Rating 200Ka@600Vac 100Ka@600Vdc I²T Clearing Rating 100k@600Vac= 60A²Seconds I²T Clearing Rating 100K@600Vdc = 40A²Seconds
Primarily Used For Semiconductor Protection 13/32"OD x 1-1/2"L (10mm x 38mm) 600V ac/dc Rated Inturrupting Rating 200Ka@600Vac 100Ka@600Vdc I²T Clearing Rating 100k@600Vac= 70A²Seconds I²T Clearing Rating 100K@600Vdc = 42A²Seconds
Primarily Used For Semiconductor Protection 13/32"OD x 1-1/2"L (10mm x 38mm) 600V ac/dc Rated Inturrupting Rating 200Ka@600Vac 100Ka@600Vdc I²T Clearing Rating 100k@600Vac= 110A²Seconds I²T Clearing Rating 100K@600Vdc = 70A²Seconds
Primarily Used For Semiconductor Protection 13/32"OD x 1-1/2"L (10mm x 38mm) 600V ac/dc Rated Inturrupting Rating 200Ka@600Vac 100Ka@600Vdc I²T Clearing Rating 100k@600Vac= 150A²Seconds I²T Clearing Rating 100K@600Vdc = 90A²Seconds
Primarily Used For Semiconductor Protection 13/32"OD x 1-1/2"L (10mm x 38mm) 600V ac/dc Rated Inturrupting Rating 200Ka@600Vac 100Ka@600Vdc I²T Clearing Rating 100k@600Vac= 180A²Seconds I²T Clearing Rating 100K@600Vdc = 110A²Seconds
Primarily Used For Semiconductor Protection 13/32"OD x 1-1/2"L (10mm x 38mm) 600V ac/dc Rated Inturrupting Rating 200Ka@600Vac 100Ka@600Vdc I²T Clearing Rating 100k@600Vac= 330A²Seconds I²T Clearing Rating 100K@600Vdc = 200A²Seconds
Primarily Used For Semiconductor Protection 13/32"OD x 1-1/2"L (10mm x 38mm) 600V ac/dc Rated Inturrupting Rating 200Ka@600Vac 100Ka@600Vdc I²T Clearing Rating 100k@600Vac= 440A²Seconds I²T Clearing Rating 100K@600Vdc = 260A²Seconds
Primarily Used For Semiconductor Protection 13/32"OD x 1-1/2"L (10mm x 38mm) 600V ac/dc Rated Inturrupting Rating 200Ka@600Vac 100Ka@600Vdc I²T Clearing Rating 100k@600Vac= 860A²Seconds I²T Clearing Rating 100K@600Vdc = 520A²Seconds
Primarily Used For Semiconductor Protection 13/32"OD x 1-1/2"L (10mm x 38mm) 100K Amp Interupting Rating Also Available in Amerages From 1A ~ 30A Can Be Used With UltraSafe Fuse Holders UPC 78200194198
Primarily Used For Control Circuits, Control Transformers, And Small Motors 13/32"OD x 1-1/2"L (10mm x 38mm) 10K Amp Interrupting Rating Fast Acting On Short Circuits Moderate Time-Delay On Inrush Currents Also Available Up To 15Amps Can Be Used With UltraSafe Fuse Holders UPC 78200190127
Primarily Used For Control Circuits, Control Transformers, And Small Motors 13/32"OD x 1-1/2"L (10mm x 38mm) 10K Amp Interrupting Rating Fast Acting On Short Circuits Moderate Time-Delay On Inrush Currents Also Available Up To 15Amps Can Be Used With UltraSafe Fuse Holders UPC 78200190126
Primarily Used For Control Circuits, Control Transformers, And Small Motors 13/32"OD x 1-1/2"L (10mm x 38mm) 10K Amp Interrupting Rating Fast Acting On Short Circuits Moderate Time-Delay On Inrush Currents Also Available Up To 15Amps Can Be Used With UltraSafe Fuse Holders UPC 78200190137
Primarily Used For Control Circuits, Control Transformers, And Small Motors 13/32"OD x 1-1/2"L (10mm x 38mm) 10K Amp Interrupting Rating Fast Acting On Short Circuits Moderate Time-Delay On Inrush Currents Also Available Up To 15Amps Can Be Used With UltraSafe Fuse Holders UPC 78200190139
Primarily Used For Control Circuits, Control Transformers, And Small Motors 13/32"OD x 1-1/2"L (10mm x 38mm) 10K Amp Interrupting Rating Fast Acting On Short Circuits Moderate Time-Delay On Inrush Currents Also Available Up To 15Amps Can Be Used With UltraSafe Fuse Holders UPC 78200190120
Primarily Used For Control Circuits, Control Transformers, And Small Motors 13/32"OD x 1-1/2"L (10mm x 38mm) 10K Amp Interrupting Rating Fast Acting On Short Circuits Moderate Time-Delay On Inrush Currents Also Available Up To 15Amps Can Be Used With UltraSafe Fuse Holders UPC 78200190142