Watlow® EZ-ZONE® Rail Mount Expansion Module (RME) Configuration Tool

NOTE: Expansion of control I/O from 6 to 24. For more information on other RM Modules and there differences, read here .

To configure your RME Module select from the following options:

  • Expansion Module
    E
  • Connector Style
     
  • Slot A
     
  • Slot B
     
  • Slot D
     
  • Slot E
     
  • Future Options
    AA
  • Additional Options
     


Your EZ-ZONE® RME Model #:



 

  • Expansion Module
    E
  • Connector Style
  • Slot A
  • Slot B
  • Slot D
  • Slot E
  • Future Options
    Not available with RME Module.AA
  • Additional Options

Connector Style

  • Right angle screw connector (standard) A
  • Front screw connector F
  • Ring lug connector (if ordered, then slots B and E must be = A) R

Slot A

  • ANone
  • C6 digital I/O
  • F3 universal process/retransmit outputs
  • J4 mechanical relay 5A, Form A
  • K2 SSRs, Form A, 10A max. each (if ordered, then slots B must be = A).
  • L4 SSR’s at 2A each. SSR’s grouped in 2-pairs with each pair sharing a common.

Slot B

  • ANone
  • C6 digital I/O
  • F3 universal process/retransmit outputs
  • J4 mechanical relay 5A, Form A
  • K2 SSRs, Form A, 10A max. each (if ordered, then slot E must be = A).
  • L4 SSR’s at 2A each. SSR’s grouped in 2-pairs with each pair sharing a common.
  • TQuad inputs for external current transformers. Can do either single-phase or three-phase system measurement for all hardware outputs ordered within the expansion module.

Slot D

  • ANone
  • C6 digital I/O
  • F3 universal process/retransmit outputs
  • J4 mechanical relay 5A, Form A
  • K2 SSRs, Form A, 10A max. each (if ordered, then slot E must be = A).
  • L4 SSR’s at 2A each. SSR’s grouped in 2-pairs with each pair sharing a common.
  • TQuad inputs for external current transformers. Can do either single-phase or three-phase system measurement for all hardware outputs ordered within the expansion module.

Slot E

  • ANone
  • C6 digital I/O
  • F3 universal process/retransmit outputs
  • L4 SSR’s at 2A each. SSR’s grouped in 2-pairs with each pair sharing a common.
  • TQuad inputs for external current transformers. Can do either single-phase or three-phase system measurement for all hardware outputs ordered within the expansion module.

Additional Options

  • AAStandard
  • ABReplacement connectors hardware only, for the entered part number. Additional cost for the model can be disregarded as you are only ordering replacement connectors.
  • 12Class 1, Div. 2 (not available with integrated limit controller or mechanical relay options).

INTERESTED IN PRODUCT

Your EZ-ZONE® RME Model #: