">

1/16 DIN

Recursos

Fabricantes

    PM6C3FK-AAAAAAA 1/16-DIN 2-Outputs

    PM6C3FK-AAAAAAA

    New

    • Replacement for Watlow 965A-3FK1-00RR
    • One Universal Input Provides Flexibility
    • Output#1 Range Selectable Analog Either 0 ~ 10Vdc  Or  0 ~ 20mA
    • Output#2 0.5A Solid State Relay (Form A)
    • Operating Voltage 12 ~ 40Vdc Or 20 ~ 28Vac
    • Auto-Tune PID Controller 
    • Also Available In 85 ~ 264Vac Model PM6C1FK-AAAAAAA

    For "How To" Videos and More Information Visit Google+ Plus

    More details

    $281.00

    Tarifas de envío

    3 Items

    • Selectable Analog Output Specifications:

      • Range Selectable Either Dc Voltage Or mA Current
      • 0 ~ 20mA ±30µA Into 800Ω Maximum Load With 5µA Resolution
      • 0 ~ 10Vdc ±15mV Into 1KΩ Minimum Load With 2.5mV Nominal Resolution
      • Scalable Output Supplies Power
      • Output May Be Used As Retransmit OrControl
      • Can Not Use Both Current & Voltage Outputs At Same Time

      Solid State Relay Form A Specifications:

      • Maximum Resistive Load 0.5A at 20 ~ 264Vac
      • Rated For Pilot Duty 20Va 120/240Vac
      • Single Pole Single Throw Normally Open Contact
      • Opto Isolated Without Contact Suppression
      • Off State Leakage Maximum 105mA
      • Output Does Not Supply Power
      • Not For Use On DC Loads

      Two Wire Bus Communication Interface Type EIA-485 Also Known As RS-485 Comes Standared With All PM Series Controllers Which Can Provide An Easy Alternative to Setting Up Program Menu Options. Various Profiles Can Be Configured And Saved As Files And Can Be Up Loaded To Other PM Controllers. USB To Serial Converter Is Required To Connect The PM Controller To Any Computer With A USB Port.

      NOTE: Switching Pilot Duty Devices Such As Control Coils For Relays Or Contactors Produces An Electro-Magnetic Force When De-Engergizing Those Type Of Loads. To Protect The Controller's Electronic Circuitry From The Inductive User Load, The Use Of An RC Suppressor Also Known As A Snubber Device Should Be Wired Between The Load And The Load Output Terminal Of The Controller. An Exception Is The Use Of Watlow Solid State Relays Having Internal RC Suppression.

      Review The Data Sheet Tab For More Specifics Or Check Out The Operator's Manual From The Download Tab

      PROGRAM FEATURESAdvanced Auto-Tune PID Control Algorithm
      AGENCY APPROVALSUL Listed, CSA, CE, RoHS, W.E.E.E. FM
      WARRANTY Three Years
      OTHER FEATURESIP2X Increases Safety For Installers And Operators

    Accessories