• 10K Amp Interrupting Rating
  • Fast Acting On Short Circuits
  • Moderate Time-Delay On Inrush Currents
  • Also Available Up To 15Amps
  • Can Be Used With UltraSafe Fuse Holders
  • UPC 78200190136
  • ">

    1/16 DIN

    Recursos

    Fabricantes

      PM6C3EJ-AAAAAAA 1/16-DIN 2-Outputs

      PM6C3EJ-AAAAAAA

      New

      • One Universal Input Provides Flexibility
      • Output#1 5A Mechanical Relay (Form C)
      • Output#2 5A Mechanical Relay (Form A)
      • Operating Voltage 12 ~ 40Vdc Or 20 ~ 28Vac
      • Auto-Tune PID Controller With Extensive Menu Options
      • Provides A Variety Of Process Control
      • Also Available In 85 ~ 264Vac Model PM6C1EJ-AAAAAAA

      For "How To" Videos and More Information Visit Google+ Plus

      More details

      $283.00

      Tarifas de envío

      5 Items

      • Electro-Mechanical Relay Form C Specifications:

        • Maximum Resistive Load 5A at 240Vac Or 30Vdc
        • 20mA at 24V Minimum Load
        • Rated For Pilot Duty 125Va at 120/240Vac And 25Va at 24Vac
        • Single Pole Double Throw Normally Open Contact
        • 100,000 Cycles at Rated Load
        • Output Does Not Supply Power
        • For Use On AC Or DC Loads

        Electro-Mechanical Relay Form A Specifications:

        • Maximum Resistive Load 5A at 240Vac Or 30Vdc
        • 20mA at 24V Minimum Load
        • Rated For Pilot Duty 125Va at 120/240Vac And 25Va at 24Vac
        • Single Pole Single Throw Normally Open Contact
        • 100,000 Cycles at Rated Load
        • Output Does Not Supply Power
        • For Use On AC Or DC Loads

        Two Wire Bus Communication Interface Type EIA-485 Also Known As RS-485 Comes Standared With All PM Series Controllers Which Can Provide An Easy Alternative to Setting Up Program Menu Options. Various Profiles Can Be Configured And Saved As Files And Can Be Up Loaded To Other PM Controllers. USB To Serial Converter Is Required To Connect The PM Controller To Any Computer With A USB Port.

        NOTE: Switching Pilot Duty Devices Such As Control Coils For Relays Or Contactors Produces An Electro-Magnetic Force When De-Engergizing Those Type Of Loads. To Protect The Controller's Electronic Circuitry From The Inductive User Load, The Use Of An RC Suppressor Also Known As A Snubber Device Should Be Wired Between The Load And The Load Output Terminal Of The Controller. An Exception Is The Use Of Watlow Solid State Relays Having Internal RC Suppression.

        Review The Data Sheet Tab For More Specifics Or Check Out The Operator's Manual From The Download Tab

        PROGRAM FEATURESAdvanced Auto-Tune PID Control Algorithm
        AGENCY APPROVALSUL Listed, CSA, CE, RoHS, W.E.E.E. FM
        WARRANTY Three Years
        OTHER FEATURESIP2X Increases Safety For Installers And Operators

      Accessories