1/8 DIN Vertical

Resources

Manufacturers

    PM8C1EC-AAAAAAA 1/8-DIN 2-Outputs

    PM8C1EC-AAAAAAA

    New

    • Output#1 Mech-Relay 5-Amp SPDT, #2 Switched dc/open Collector
    • One Universal Input
    • 100 ~ 240V-ac Auto-Tune PID Controller With Extensive Full Features Menu
    • Also Available In 24V-Ac 12~24V-Dc Model PM8C3EC-AAAAAAA
    • Also Available In Horizontal Panel Mount Model PM9C1EC-AAAAAAA
    • Standard Bus Communications

    For "How To" Videos and More Information Visit Google+ Plus

    More details

    $279.00

    Shipping Rates

    4 Items Available

    • Electro-Mechanical Relay Form C Specifications:

      • Maximum Resistive Load 5A at 240Vac Or 30Vdc
      • 20mA at 24V Minimum Load
      • Rated For Pilot Duty 125Va at 120/240Vac And 25Va at 24Vac
      • Single Pole Double Throw Normally Open Contact
      • 100,000 Cycles at Rated Load
      • Output Does Not Supply Power
      • For Use On AC Or DC Loads

      Switched DC Specifications:

      • 30mA DC Maximum Supply Current
      • Short Circuit Limited to < 50mA
      • 22 ~ 32V -DC Open Circuit Voltage
      • Drives External Relay Using dc- and dc+

      Open Collector Specifications:

      • Current Sinking Output @ 100mA Maximum
      • Maximum Supply Voltage -30Vdc
      • For DC Loads An External Power Supply Is Required
      • Connect Load Negative To Open Collector

      Two Wire Bus Communication Interface Type EIA-485 Also Known As RS-485 Comes Standared With All PM Series Controllers Which Can Provide An Easy Alternative to Setting Up Program Menu Options. Various Profiles Can Be Configured And Saved As Files And Can Be Up Loaded To Other PM Controllers. USB To Serial Converter Is Required To Connect The PM Controller To Any Computer With A USB Port.

      NOTE: Switching Pilot Duty Devices Such As Control Coils For Relays Or Contactors Produces An Electro-Magnetic Force When De-Engergizing Those Type Of Loads. To Protect The Controller's Electronic Circuitry From The Inductive User Load, The Use Of An RC Suppressor Also Known As A Snubber Device Should Be Wired Between The Load And The Load Output Terminal Of The Controller. An Exception Is The Use Of Watlow Solid State Relays Having Internal RC Suppression.

      Review The Data Sheet Tab For More Specifics Or Check Out The Operator's Manual From The Download Tab

      PROGRAM FEATURESAdvanced Auto-Tune PID Control Algorithm
      AGENCY APPROVALSUL Listed, CSA, CE, RoHS, W.E.E.E. FM
      WARRANTY Three Years
      OTHER FEATURESIP2X Increases Safety For Installers And Operators